Application Conditions For Conventional Paint Systems
Sur-Prep® AP-1 should be applied when application temperatures are between 65°F and 90°F (18°C and 32°C) with a relative humidity of less than 70%.
The table below shows the topcoats cured between 65°F and 90°F (10°C and 32°C) that can be chemically reactivated with Sur-Prep® AP-1.
IS 900 Ty III
TOPCOAT BASE AND CURING SOLUTION COMPONENT |
PREVIOUSLY APPLIED TOPCOAT |
PREVIOUSLY APPLIED TOPCOAT THINNER |
SUBSEQUENTLY APPLIED |
Akzo Nobel:
PRC Desoto:
|
All Colors, Not Clears (Note 5) |
CA8000C, CA8000C1, CA8000C2, or any blend of these thinners |
All Colors or Clears |
Sky Hullo: |
All Colors or Clears (Note 1) |
IS 900 Ty III |
All Colors |
Akzo Nobel:
PRC Desoto:
|
All Colors or Clears |
TR-109 or TR-112 (Note 2) |
All Colors or Aerodur 3002 Clearcoats (Note 6) |
Application Conditions for Conventional Paint Systems Notes
Note 1: Previously applied topcoat shall be overcoated within 72 hours after its application.
Note 2: The volume of TR-112 thinner used shall not exceed one part of TR-112 to four parts of TR-109.
Note 3: Applicable to Desothane HS CA 8000 series only.
Note 4: Applicable to Eclipse ECL-G series only.
Note 5: Application of Sur-Prep® AP-1 over CA 8000 Clear may result in poor adhesion of the subsequent topcoat (Color or Clear).
Note 6: Application of Sur-Prep® AP-1 between Eclipse (Color or Clear) topcoat and subsequently applied Eclipse Clear topcoat may result in hazing appearance issues. No appearance defects, such as hazing, occur when Aerodur 3002 clearcoat is applied over Sur-Prep® AP-1.
Note 7: Once applied, the surface coated with Sur-Prep® AP-1 shall not be touched or disturbed prior to application of any subsequent coating.
The table below shows the topcoats cured above 90°F (32°C) that can be chemically reactivated with Sur-Prep® AP-1.
TOPCOAT BASE AND CURING SOLUTION COMPONENT |
PREVIOUSLY APPLIED TOPCOAT | PREVIOUSLY APPLIED TOPCOAT THINNER | MAX CURE LIMIT ABOVE 90°F (32°C) OF PREVIOUSLY APPLIED TOPCOAT |
SUBSEQUENTLY APPLIED TOPCOAT |
Akzo Nobel:
PRC Desoto:
|
All Colors, Not Clears (Note 6) |
CA8000C, CA8000C1, CA8000C2, or any blend of these thinners |
Unlimited hours- Cure not to exceed 180° F (82°C) (Note 5) |
All Colors or Clears |
PRC Desoto:
|
All Colors, Not Clears |
CA8000C, CA8000C1, CA8000C2, or any blend of these thinners |
Unlimited hours-Cure not to exceed 180° F (82°C) (Note 5) |
All Colors or Clears |
Akzo Nobel:
PRC Desoto:
|
All Colors or Clears |
TR-109 | 12 Hours-Cure not to exceed 105°F (41°C) 8 Hours-Cure exceeds 105°F (41°C), but not to exceed 120°F (49°C) 8 Hours-Cure not to exceed 105°F (41°C) |
All Colors or Aerodur |
Sky Hullo: |
All Colors |
IS 900 Ty III | 8 Hours-Cure not to exceed 120°F (49°C) (Note 5) |
All Colors |
PRC Desoto:
Desothane HS CA 8800 |
All Colors or Clears |
CA8880CTP or CA8800CTP1 or CA8800CTR | 12 Hours – Cure not to exceed 120°F (49°C) |
All Colors or Clears |
Akzo Nobel:
PRC Desoto:
|
All Colors or Clears |
TR-109 or TR-112 (Note 2) |
8 Hours-Cure not to exceed 105°F (41°C) |
All Colors or Aerodur |
Application Conditions for Conventional Paint Systems Notes
Note 1: Previously applied topcoat shall be overcoated within 72 hours after its application.
Note 2: The volume of TR-112 thinner used shall not exceed one part of TR-112 to four parts of TR-109.
Note 3: Applicable to Desothane HS CA 8000 series only.
Note 4: Applicable to Eclipse ECL-G series only.
Note 5: This includes topcoated surfaces where the amount of drying/curing experienced by the topcoat and/or the curing temperature is unknown.
Note 6: Application of Sur-Prep® AP-1 over CA 8000 Clear may result in poor adhesion of the subsequent topcoat (Color or Clear).
Note 7: Application of Sur-Prep® AP-1 between Eclipse (Color or Clear) topcoat and subsequently applied Eclipse Clear topcoat may result in hazing appearance issues. No appearance defects, such as hazing, occur when Aerodur 3002 clearcoat is applied over Sur-Prep® AP-1.
Note 8: Once applied, the surface coated with Sur-Prep® AP-1 shall not be touched or disturbed prior to application of any subsequent coating.